Fluke 705, Loop Calibrator Call Irfan 085282731888/ 081908101888

Overview
The new Fluke 705 Loop Calibrator is a cost-effective, integrated solution for calibration, repair and maintenance of current loops. It features:

mA sourcing, simulation and measurement
0.02% accuracy and 0.001 mA resolution
Simultaneous mA and % of span display
Selectable step or ramp outputs
24 V Loop supply with mA measure
0-28 VDC measurement to check Loop Voltage
Easy battery exchange without opening the case
Compact case with separate protective holster

Low cost calibrator muscle.
For a powerful loop calibrator at a very affordable price, choose the new Fluke 705 Loop Calibrator. This feature-rich solution to loop calibration, maintenance and repair offers:

A large display and simple, pushbutton interface for ease of use.
Simultaneous mA and % readout for quick, easy interpretation of readings.
mA accuracy of 0.02%
Push button 25% steps for fast, easy linearity checks. Save time over traditional knob type controls.
" Span Check " for fast confirmation of zero and span.
Selectable slow ramp, fast ramp, and step to provide smooth outputs for valve slewing and loop functional tests.
24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
Single 9V battery that is easily changed.
0 - 20 mA or 4 - 20 mA default start up modes.
Safety conformance CSA C22.2 No. 1010.1: 1992

Specifications
Current Measurement
Range: 0 to 24 mA
Resolution: 0.001 mA
Accuracy: 0.02% Rdg + 2 LSD
Current Sourcing
Range: 0 to 20 mA or 4 to 20 mA
Accuracy: 0.025% Rdg + 2 LSD
Drive Capability: 1000 ï ¿ ½ @ 24 mA
Current Simulation
Range: 0 to 20 mA or 4 to 20 mA
Accuracy: 0.025% Rdg + 2 LSD
Ext. loop voltage requirement: 12-30 V
Loop Power
While measuring mA, 24 V
Voltage measurement
Range: 0 to 28 V DC
Resolution: 1 mV
Accuracy: 0.025% Rdg + 2 LSD

Environmental Specifications
Operating Temperature
-10 ï ¿ ½ C to 55 ï ¿ ½ C
Storage Temperature
-40 ï ¿ ½ C to 60 ï ¿ ½ C
Humidity ( Without Condensation)
0 to 90% ( 0 ï ¿ ½ C to 35 ï ¿ ½ C) ; 0 to 70% ( 35 ï ¿ ½ C to 55 ï ¿ ½ C)
Temperature Coefficient
-10 ï ¿ ½ C to 18 ï ¿ ½ C, 28 ï ¿ ½ C to 55 ï ¿ ½ C, ï ¿ ½ .005% of range per ï ¿ ½ C

Safety Specifications
Safety
CSA C22.2 No. 1010.1: 1992
EMC
EN50082-1: 1992 and EN55022: 1994 Class B
Maximum voltage
30 V

Mechanical & General Specifications
Size
152 x 70 x 41 mm
Weight
340g
Batteries
One 9V battery
Shock & Vibration
per MIL-T-28800 for a Class 2 Instrument
Display current and % of span
Yes
Auto step, auto ramp
Yes
Span Check
Yes

including:
AC70A Alligator Clips
C10 protective yellow holster with Flex-Standï ¿ ½
Instruction sheet
TL75 safety-designed test lead set
NIST- traceable calibration report and data

Hubungi Buana Survey
Jl. Ciledug Raya Komplek. Taman Surya Buana Blok L19 - Kreo - Cipadu, Ciledug - Tangerang 15155
CP : Irfan Syihabudin
XL : 081908101888
AS : 085282731888